HR097-053D024H
Brand:Henry
Model:HR097-053D024H
Category:blowers
Sales Hotline:+86 10-62547612
Cell Phone:+86 187 0152 6587
E-mail: Jason@bjhengrui.cn / Ada@bjhengrui.cn / qin@bjhengrui.cn
- Specification
- Details
- Application
henry fan | model:HR097-053D024H | sufficient stock
DC Single Inlet Blower Fan Ø97mm
henry fan——HR097-053D024H——Nominal data:
Fan type: Single Inlet Blower Fan
Model no.: HR097-053D024H
Rated Voltage: 24VDC
Impeller Size: Ø097mm
Rated Speed: 2500RPM
Air Flow: 125M³/H
Motor Type: Brushless DC(BLDC) external rotor motor
Impeller Material : Galvanized Metal Sheet
Type of Protection :IP44
Insulation Class :B
Speed Control :0-10VDC/PWM
Bearing :Ball Bearing
model rated operating rated rated rated air air noise perm.amb. weight
voltage voltage current power speed flow pressure level temp.
part no. V VDC A W RPM M3/H Pa dBA ℃ Kg
HR097-053D024H 24 16-28 0.92 22 2500 125 278 60 -25——60 0.63
henry fan——HR097-053D024H——Structural drawing:
henry fan——HR097-053D024H——air flow:
We can also provide customized solutions according to your needs.You have the following options:
EC Motor Controller Series:
Input voltage range :110VAC/230VAC
Input power range :10W~2000W
Maximum speed range :60 000 RPM
Technical characteristics:
Insensitive FOC Chord Control
PFC Power Factor Compensation
Constant Speed, Constant Current and Closed Loop Control
Maximum speed range :60 000 RPM
Overvoltage and undervoltage, over-current, blocking and phase-gap protection
DC Motor Controller Series:
Input voltage range :12VDC~110VDC
Input power range :10W~2000W
Maximum speed range :60 000 RPM
Technical characteristics:
Insensitive FOC Chord Control
Constant Speed, Constant Current and Closed Loop Control
Maximum speed range :60 000 RPM
Overvoltage and undervoltage, over-current, blocking and phase-gap protection
For more information,please contact:
Wechat:+86 18701526587 / +86 15010372387
Skype: bjhengryRP1983@hotmail.com
bjhengry2018@gmail.com
henry fan | model:HR097-053D024H | sufficient stock
DC Single Inlet Blower Fan Ø97mm
henry fan——HR097-053D024H——Nominal data:
Fan type: Single Inlet Blower Fan
Model no.: HR097-053D024H
Rated Voltage: 24VDC
Impeller Size: Ø097mm
Rated Speed: 2500RPM
Air Flow: 125M³/H
Motor Type: Brushless DC(BLDC) external rotor motor
Impeller Material : Galvanized Metal Sheet
Type of Protection :IP44
Insulation Class :B
Speed Control :0-10VDC/PWM
Bearing :Ball Bearing
model rated operating rated rated rated air air noise perm.amb. weight
voltage voltage current power speed flow pressure level temp.
part no. V VDC A W RPM M3/H Pa dBA ℃ Kg
HR097-053D024H 24 16-28 0.92 22 2500 125 278 60 -25——60 0.63
henry fan——HR097-053D024H——Structural drawing:
henry fan——HR097-053D024H——air flow:
We can also provide customized solutions according to your needs.You have the following options:
EC Motor Controller Series:
Input voltage range :110VAC/230VAC
Input power range :10W~2000W
Maximum speed range :60 000 RPM
Technical characteristics:
Insensitive FOC Chord Control
PFC Power Factor Compensation
Constant Speed, Constant Current and Closed Loop Control
Maximum speed range :60 000 RPM
Overvoltage and undervoltage, over-current, blocking and phase-gap protection
DC Motor Controller Series:
Input voltage range :12VDC~110VDC
Input power range :10W~2000W
Maximum speed range :60 000 RPM
Technical characteristics:
Insensitive FOC Chord Control
Constant Speed, Constant Current and Closed Loop Control
Maximum speed range :60 000 RPM
Overvoltage and undervoltage, over-current, blocking and phase-gap protection
For more information,please contact:
Wechat:+86 18701526587 / +86 15010372387
Skype: bjhengryRP1983@hotmail.com
bjhengry2018@gmail.com
Henry fans can be used in HVAC,Telecom,FFU,Home Appliance,Electronic Cooling,Air Purifier and others.
Ventilation
Ventilation, Henry DC/EC axial fans, forward curved centrifugal fans, backward curved centrifugal fans are used in shopping malls, offices, hotels, swimming pool halls, meeting halls, and shopping centers where HVAC system is installed.
Air Handling Unit
Henry forward curved centrifugal fans and backward curved centrifugal fans are widely applied in AHU all over the world. Air handling unit (often abbreviated to AHU), is a device used to regulate and circulate air as part of a heating, ventilating, and air-conditioning (HVAC) system.
Heat Recovery System
Heat recovery ventilation (HRV) is an energy recovery ventilation system using equipment which employs a cross flow or counter-flow heat exchanger (countercurrent heat exchange) between the inbound and outbound air flow.
Telecom Station
Telecommunication System, Henry DC axial fans, backward curved centrifugal fans are being used by network suppliers, telecom operators who use the units for electronics cooling in telecom base stations, telecom shelter,BTS site .
Air Purifier
Air Purifier, With high efficiency and flexible speed control function, Henry forward curved centrifugal fans and plastic impeller backward curved centrifugal fans are popular in air purifier industry.
FFU Application
We have cooperated with a lot of companies . they are mainly focus on FFU system manufacture. The main fans which are used in FFU is the 310mm-400mm backward curved centrifugal fan. We also help to develop related control system for an more intelligent control solutions.
Kitchen & Home Appliance
Henry fans are been installed in the Kitchen & Home Appliance for exhausting airs or electronic cooling. The picture is one of the application cases for one of our Clients - exhaust canopy.
Electronic Cooling
Henry Axial fans and centrifugal fans are been in electronic cooling with the advantage of long life span, stable performance. Signal output can help to remote control of the cooling system.
Henry also has other fans, the models are as follows:
HR160-092D024/48M
HR140-092D048H
HR140-072D024/48M
HR133-072D024/48H
HR120-072D048M
HR097-053D024H
For more information,please contact:
Wechat:+86 18701526587 / +86 15010372387
Skype: bjhengryRP1983@hotmail.com
bjhengry2018@gmail.com