ZIEHL-ABEGG Data Center Fans
Brand:ZIEHL-ABEGG
Model:
Category:Centrifugal fans
Sales Hotline:+86 10-62547612
Cell Phone:+86 187 0152 6587
E-mail: Jason@bjhengrui.cn / qin@bjhengrui.cn
- Specification
- Details
- Application
MODEL |
Article Code |
Voltage (v) |
Frequency (Hz) |
Size (mm ) |
Air Flow (m³/h) |
Pressure (Pa) |
Power (kW) |
RH35I-ZID.DC.CR |
116863 |
1~230 |
50/60 |
355 |
6634 |
1072 |
1.35 |
RH35I-ZID.DC.CR |
116864 |
3~400/460 |
50/60 |
355 |
8275 |
1666 |
2.50 |
RH35V-ZIK.DC.VR |
116469/116198
|
3~230/400/460
|
50/60
|
355
|
7088/6806
|
899/827
|
1.70/1.50
|
RH56V-ZIK.GL.VR |
117772/116763 |
3~230/400/460 |
50/60 |
560 |
16103/17372 |
673/782 |
2.80/3.50 |
RH56I-ZID.GL.CR |
116880
|
3~400/460
|
50/60
|
560
|
18659
|
1272
|
4.60
|
RH56I-ZID.GG.CR |
116879 |
3~400/460 |
50/60 |
560 |
16830 |
1036 |
3.40 |
RH63V-ZIK.GL.VR |
117835/118068
|
3~230/400/460
|
50/60
|
630
|
17518/20582
|
501/686
|
2.20/3.50
|
Data Center
When it comes to cooling and ventilating data centers large and small, operators can save a great deal of energy by putting their trust in energy-efficient air conditioners, fans, and control technology.
so good centrifugal fans for data center features:
- Outstanding failure safety
- Precise controllability
- A long service-life
- Easy maintenance
Application
Computer Room Air Conditioners (CRAC)
operate in a similar way to air conditioning systems with a mechanical (air) cooling system.
The air is then cooled using a refrigerant and then fed back to the racks through a double floor .
|
|
Computer Room Air Handlers (CRAH)
remove the heat from server rooms using a ventilation unit and fans. The air conditioner is often located outdoors, whether on the roof or on the side of the data center.
The supply air is cooled using chillers and transported back into the server room.
|
The ziehl-abegg is the answer to all your requirements in regards to perfect ventilation with high volumes.
Products Highlight for Data Center
Computer Room Air Conditioners (CRAC)
operate in a similar way to air conditioning systems with a mechanical (air) cooling system.
The air is then cooled using a refrigerant and then fed back to the racks through a double floor .
|
|
Computer Room Air Handlers (CRAH)
remove the heat from server rooms using a ventilation unit and fans. The air conditioner is often located outdoors, whether on the roof or on the side of the data center.
The supply air is cooled using chillers and transported back into the server room.
|